Q U I CK CH I L LE R • M N -3 6 5 80 ( RE V . 0 ) • I N ST A L LA T I ON / O PE R A TI O N /S ER V I CE M A N UA L • 34.
Error code Action Required
E-10 – Cavity Sensor Shorted
This error message indicates a problem with the interior cavity sensor. The Quickchiller
will not operate in any operational mode. Call service.
E-11 – Cavity Sensor Open
This error message indicates a problem with the interior cavity sensor. The Quickchiller
will not operate in any operational mode. Call service.
P-10 – Probe 1 shorted
This error message indicates a problem with the Probe 1. The Quickchiller will operate
normally in the Time mode but will not operate in the Probe mode. Call service.
P-20 – Probe 2 shorted
This error message indicates a problem with the Probe 2. The Quickchiller will operate
normally in the Time mode but will not operate in the Probe mode. Call service.
P-30 – Probe 3 shorted
This error message indicates a problem with the Probe 3. The Quickchiller will operate
normally in the Time mode but will not operate in the Probe mode. Call service.
C-10 – Coil sensor shorted
This error message indicates a problem with the display identied coil sensor. The
Quickchiller will not operate in any operational mode. Call service.
C-11 – Coil sensor open
This error message indicates a problem with the display identied coil sensor. The
Quickchiller will not operate in any operational mode. Call service.
E-80 – EEPROM error
This error message indicates the control memory is not correctly reading user-set
values. The Quickchiller will remain operational but the user dened settings will be
reloaded to the default values. The control will revert to factory default settings and
will require operator modication each time the unit is used. Call Service.
E-83 – EEPROM not repsonding
EEPROM not responding. Call service.
E-84 – EEPROM User Options Error
User options error. Turn unit on and off to reset. If problem persists call Service
E-53 – Control hardware error
Fatal error. Unit will not opperate. Call service.
E-54 – Control hardware error
Fatal error. Unit will not opperate. Call service.
E-66 – Control processor reset
Processor reset on control board. Call Service.
E-70 – Personality changed
Control Board personality changed during operation. Call Service.
E-77 – Defrost overdue
Unit is more than 1 hr overdue for defrost. Defrost chiller. If error persists call Service.
E-94 – Communication failure
Interface board and control board not communicating. The Quickchiller will not operate
in any mode. Call Service.
TROUBLESHOOTING