Use an approved
gas pipe sealant at
allexternalthreaded
connections, gas
piping used on gas
connections must
avoid sharp bends
that may restrict the
flow of gas to the
appliance. If the
connected pressure
exceeds14.0”W.C.(3.5kPa),astep-downregulatoris
required to be supplied by the owner/operator.
Close the individual manual shut-off valve to
isolate the fryer from the gas supply piping system
during any pressure testing at test pressures equal
to or less than
1
/
2
psig.(3.4kPa).Thefryerand
individual shut-off valve must be disconnected
from the gas supply piping system during
any pressure testing at pressures in
excessof1/2psig.(3,4kPa).
In the U.S.A., installation must conform to local
codes or, in the absence of local codes, with the
current edition of the National Fuel Gas Code,
NFPA-54andANSIZ83.11aCSA1.8a2004(or
latestedition).InCanada,installationmustbein
accordancewithlocalcodes,CAN/CGA-B149.1,
Installation for Natural Gas Burning Appliances
and Equipment(latestedition)orCAN/
CGA-B149.2Installation for Propane Burning
Appliances and Equipment(latestedition).
The inlet supply line must be properly sized
to accommodate all individual appliances
simultaneously used on the same line but must
neverbesmallerthan3/4 I.D.
LEAK TESTING
Installation requires gas leak testing on all gas
piping and fittings. Use an approved electronic
leak device or a soap and water solution at all gas
connections. If bubbling appears when using a soap
and water solution, the connection must be refitted.
Never use an open flame to leak test.
INCORRECT CORRECT
A
B
C
D
E
F
G
H
GAS INTAKE
A-G Installation elbow
B Wall Valve
C-D Three-piece union fitting
(minimum 1 per installation)
E-F End connector for the flexible tube
H Marking line
GAS CONNECTION
DANGER
Installation, air adjustment and/or
service work must be in accordance
with all local codes and must be
performed by a certifi ed service
technician qualifi ed to work on
gas appliances.
DANGER
NEVER USE AN OPEN
FLAME TO LEAK TEST.
INSTALLATION
Gas Fryer Operation & Care Manual 9